LP PYRA 02
LP PYRA 03
LP PYRA 12
LP PYRA 02
LP SP1
CPM 12 AA4...
LP PYRA 02
10000 nm
EA-14
Delta Ohm manufactures First Class
LP PYRA 02
and
LP PYRA 12
and Second
Class
LP PYRA 03
pyranometers which fully comply with ISO 9060 standards, and
meet the requirements defined by the World Meteorological Organization (WMO).
These are strong and reliable instruments, especially designed to be used under all
weather conditions. They are suitable for installation on the field.
Recommended use:
atmospheric research, weather stations, climatology, energy
saving research, productive efficiency test of photovoltaic plants, etc...
Pyranometers LP PYRA 02 and LP PYRA 03 are well suited for the measurement of
incoming global solar radiation (0.3μm...3μm spectral range). LP PYRA 12 shadow
ring is designed to shield the instrument sensor from direct radiation; by that, an
exact measurement of the diffuse sky radiation is possible.
LP PYRA 0x
with direct, unamplified output, no external power supply
required
LP PYRA 0x AC with 4..20 mA current output- 2-wire connection, requires external
power supply
LP PYRA 0x AV with 0..1Vdc, 0..5Vdc or 0..10 Vdc voltage output, requires external
power supply
LP PYRA 0x S
with serial RS485 and MODBUS-RTU protocol, requires external
power supply
The pyranometers with unamplified output have a typical sensitivity of:
10
mV
K7sM
-2
Every pyranometer is calibrated separately and is supplied standard with a WRR
(World Radiometric Reference) Report of Calibration.
Technical Specification
LP PYRA 02 / LP PYRA 12
LP PYRA 03
Typical sensitivity
10 μV/(W/m
Shadow ring for LP PYRA 12
Weight
5.90 Kg
Diameter
570 mm
Height
54 mm
Basis diameter
300 mm
ORDERING CODE
LP PYRA 02:
First class pyranometer according to ISO 9060. Complete with: shade
disk LP SP1, desiccant sachet with silica-gel crystals, 2 cartridges, spirit
level,
M12
4-pole connector and Report of Calibration. Typical sensitivity
10μV/(W/m²).
Connection cable has to be ordered separately
.
LP PYRA 02AC:
First class pyranometer according to ISO 9060. Complete with
shade disk LP SP 1, desiccant sachet with silica-gel crystals, 2 cartridges,
spirit level,
M12
4-pole connector and Report of Calibration.
Connection
cable has to be ordered separately. Current output 4...20mA
. 4mA =
0W/m
2
, 20mA = 2000W/m
2
. Power supply: 10...30Vdc.
LP PYRA 02AV: First class
pyranometer according to ISO 9060. Complete with
shade disk LP SP 1, desiccant sachet with silica-gel crystals, 2 cartridges,
spirit level,
M12
4-pole connector and Report of Calibration.
Voltage output
LP PYRA 02 - LP PYRA 03 - LP PYRA 12
PYRANOMETERS
Typical spectral response
Relative spectral response
E
Serial output RS485 MODBUS-RTU
. Power supply:
5...30Vdc.
LP S1:
Mounting kit for LP PYRA 02: bracket for attachment to a mast, including
fasteners and leveling screws.
LP SP1:
Shade disk for LP PYRA 02
LP RING 02:
Base with levelling device and adjustable holder for mounting the LP
PYRA 02 pyranometers in an inclined position. Not suitable for LP PYRA02AV,
LP PYRA02AC.
LP SG:
Drying cartridge with silicagel crystals, complete with O-ring.
LP G:
Pack of 5 cartridges of silicagel.
LP PYRA 03:
Second class pyranometer according to ISO 9060. Complete
with spirit level,
M12
4-pole connector and Report of Calibration. Typical
sensitivity 10μV/(W/m
2
).
Connection cable has to be ordered separately.
LP PYRA 03AC:
Second class pyranometer according to ISO 9060. Complete with
spirit level,
M12
4-pole connector and Report of Calibration. Typical sensitivity
10μV/(W/m
2
).
Connection cable has to ordered separately
.
Current output
4...20mA
. 4mA = 0W/m
2
, 20mA = 2000W/m
2
. Power supply: 10...30Vdc.
LP PYRA 03AV:
Second class pyranometer according to ISO 9060. Complete with
spirit level,
4-pole connector and Report of Calibration
. Typical sensitivity
10μV/(W/m
2
).
Connection cable has to ordered separately
.
Voltage output
0...1Vdc, 0...5Vdc, 0...10Vdc
. 0V = W/m
2
, 1/5/10Vdc = 2000W/m
2
. Power
supply: 10...30Vdc (15...30Vdc for models with output 0...10Vdc).
LP PYRA 03 S:
Second class pyranometer according to ISO 9060. Complete with
spirit level,
8-pole connector and Report of Calibration
. Typical sensitivity
10μV/(W/m
2
).
Connection cable CPM12-8P...
with M12 connector with 2, 5
or 10m length have to be ordered separately.
Serial output RS485 MODBUS-
RTU
. Power supply: 5...30Vdc.
LP RING 03
: Base with levelling device and adjustable holder for mounting the LP
PYRA 03 pyranometer in an inclined position.
LP S2:
Mounting kit: spirit level and stud for mounting LP PYRA 03 on a support
which is also part of the kit. Fasteners, shade disk LP SP2 are included.
LP SP2:
Shade disk.
LP S3:
Attachment bracket for pyranometers LP PYRA 03, LP PYRA03AC...AV.
Suitable for mast with diameter of 40÷50mm.
LP S6:
Kit for the installation of LP PYRA 02 and LP PYRA 03 pyranometers. The
kit includes: 1 m mast (LP S6.05), base fitting (LP S6.04), graduated support
plate (LP S6.01), bracket for HD9007 or HD32MTT.03.C (HD 9007T29.1),
bracket for pyranometers (LP S6.03).
LP PYRA 12:
First Class Pyranometer (LP PYRA 02) according to ISO 9060.
Complete with shade disk, shadow ring for diffuse radiation, drying cartridge
for silicagel crystals, 2 silicagel cartridges and Report of Calibration. M12
4-pole connector. Typical sensitivity 10μV/(W/m
2
).
Connecting cable has to
be ordered separately
.
HD 9007.T29.1:
White powder-coated anticorodal aluminium mounting bracket.
Supplied with screws for fixing to the LPS6.01 support. For the air temperature
probe TP32MTT.03.C or the protection from solar radiations HD9007.
HD 9007.T29K:
White powder-coated anticorodal aluminium mounting bracket.
Supplied with accessories for fixing to a Ø 25...44 mm mast. For the air
temperature probe TP32MTT.03.C.
LP PYRA 12AC: First Class
Pyranometer (LP PYRA 02) according to ISO 9060.
Complete with shade disk, shadow ring for diffuse radiation, drying cartridge
for silicagel crystals, 2 silicagel cartridges and Report of Calibration. M12
4-pole connector. Typical sensitivity 10μV/(W/m
2
).
Connection cable has to
ordered separately
.
Current output
4...20mA
. 4mA = 0W/m
2
, 20mA =
2000W/m
2
. Power supply: 10...30Vdc.
LP PYRA 12AV: First Class
Pyranometer (LP PYRA 02) according to ISO 9060.
Complete with shade disk, shadow ring for diffuse radiation, drying cartridge
for silicagel crystals, 2 silicagel cartridges and Report of Calibration. M12
4-pole connector. Typical sensitivity 10μV/(W/m
2
).
Connection cable has to
be ordered separately
.
Voltage output
0...1Vdc, 0...5Vdc, 0...10Vdc
. 0V
= W/m
2
, 1/5/10Vdc = 2000W/m
2
. Power supply: 10...30Vdc (15...30Vdc for
models with output 0...10Vdc).
LP PYRA 12 S : First Class
Pyranometer (LP PYRA 02) according to ISO 9060.
Complete with shade disk, shadow ring for diffuse radiation, drying cartridge
for silicagel crystals, 2 silicagel cartridges and Report of Calibration. Typical
sensitivity 10μV/(W/m
2
).
Connection cable
CPM12-8P...
with M12 connector
with 2, 5 or 10m length have to be ordered separately.
Serial output RS485
MODBUS-RTU
. Power supply: 5...30Vdc.
LP RING 12:
Ring base for measuring the diffuse radiation, for LP PYRA 12.
LP RING 02:
Base with levelling device and adjustable holder for mounting the LP
PYRA 02 pyranometers in an inclined position.
Connection cables for LP PYRA 02... - 03...- 12...
CPM12 AA4.2:
4-pole cable. Length 2m. 4-pole M12 connector on one end, open
wires on the other side
CPM12 AA4.5:
4-pole cable. Length 5m. 4-pole M12 connector on one end, open
wires on the other side
CPM12 AA4.10:
4-pole cable. Length 10m. 4-pole M12 connector on one end,
open wires on the other side
CPM12-8P.2:
8-pole cable. Length 2m. 8-pole M12 connector on one end, open
wires on the other side (only for LP PYRA...S)
CPM12-8P.5:
8-pole cable. Length 5m. 8-pole M12 connector on one end, open
wires on the other side (only for LP PYRA...S)
CPM12-8P.10:
8-pole cable. Length 10m. 8-pole M12 connector on one end, open
wires on the other side (only for LP PYRA...S)
CP 24:
PC connecting cable for the RS485 MODBUS-RTU parameters configuration
of the LP PYRA...S pyranometers. With built-in RS485/USB converter. 8-pole
M12 connector on instrument side and A-type USB connector on PC side.
Supplied with a CD-ROM including the USB drivers and a software for the
Modbus connection to PC.
HD978TR3:
Configurable signal converter amplifier with
4÷20mA (20÷4mA)
output. Input measuring range -10..+60mV. Default setting 0÷20mV.
Minimum measuring range 2mV.
HD978TR4:
Configurable signal converter amplifier with 0÷10 (10÷0Vdc) output.
Input measuring range -10..+60mV. Default setting 0÷20mV.
Minimum measuring range 2mV.
HD978TR5:
Wall configurable, signal converter amplifier with 4÷20mA (20÷4mA)
output. Input measuring range –10...+60mV. Default settings 0÷20mV.
Minimum measuring range 2mV.
HD978TR6:
Wall configurable, signal converter amplifier with 0÷10 (10÷0Vdc)
output. Input measuring range –10...+60mV. Default settings 0÷20mV.
Minimum measuring range 2mV.
HD 778 TCAL:
Voltage generator
in the range -60mVdc...+60mVdc, controlled
by PC through the RS232C serial port,
DELTALOG-7
software for setting of
HD 978TR3, HD 978TR4, HD978TR5, HD978TR6 converters.