HD21AB  and
HD21AB17
  IAQ  Monitors  are  bench-top/portable  instruments
manufactured  by Delta  Ohm  for  the  analysis  of  indoor  air  quality  (IAQ,  Indoor Air Quality).
The instruments simultaneously measure the parameters:
• Carbon Dioxide CO2
• Carbon Monoxide CO
• Atmospheric Pressure The HD21AB17 instrument also measures:
• Temperature
• Relative Humidity
and it calculates:
• Dew Point
• Wet Bulb Temperature
• Absolute Humidity
• Mixing Ratio
• Enthalpy
HD21AB  and HD21AB17  are  dataloggers  with  a  memory  capacity  of  67600 recordings, divided in 64 blocks. They use the DeltaLog10 software from version 0.1.5.3.
Reference  Standards:
ASHRAE  62.1    2004, Legislative  Decree  81/2008.
These  regulations  apply  to  all  confined  spaces  that  could  be  used  by  people.
Kitchens, baths, changing rooms and swimming pools are included, due to the
presence of high humidity. You should take into account, in regard to air quality,
possible chemical, physical and biological contaminants.
The  instruments  have  a  wide  Dot  Matrix  graphic  display  with  a  resolution  of
160x160 dots.
The instruments typical applications are:
• Measurement  of  IAQ  (Indoor Air  Quality)  and  comfort  conditions  in  schools, offices and indoor spaces.
• Analysis and study of the Sick Building Syndrome, and of the resulting consequences.
• Checking the HVAC (Heating,  Ventilation  and  Air  Conditioning)  system  efficiency.
• Examination of IAQ conditions in factories to optimize microclimate and improve productivity.
• Building Automation checks.
Instrument Technical Data
Instrument
Dimensions
(Length x Width x Height)
210x90x40 mm (HD21AB)
300x90x40 mm (HD21AB17 with probe)
Weight
470 g (batteries included)
Materials
ABS, rubber
Display
Backlit, Dot Matrix
160x160 dots, visible area 52x42 mm
Operating conditions
Operating temperature
-5...50°C
Storage temperature
-25...65°C
Working relative humidity
0 ... 85% RH without condensation
Instrument uncertainty
± 1 digit @ 20°C
Power
Mains adapter (code SWD10)
12Vdc/1A
Batteries
4 x 1.2V NiMH rechargeable batteries AA type
Autonomy
8 hours of continuous use in measure mode
Power absorbed
with instrument off
< 45μA
Security of stored data
Unlimited
Serial interface:
Socket:
mini-USB
Type:
USB 1.1 or 2.0 not insulated
Baud rate:460800
Data bits:8
Parity:None
Stop bits:1
Flow control:Xon-Xoff
Cable length:Max 5 m
Memory
Divided in 64 blocks.
Storage capacity
67600 recordings.
Logging interval
Selectable among: 15, 30 seconds, 1, 2, 5, 10,
15, 20, 30 minutes and 1 hour.
 
Logging interval
Storage capacity
Logging interval
Storage capacity
15 seconds
About 11 days and 17 hours
10 minutes
About 1 year and 104 days
30 seconds
About 23 days and 11 hours
15 minutes
About 1 year and 339 days
1 minute
About 46 days and 22 hours
20 minutes
About 2 years and 208 days
2 minutes
About 93 days and 21 hours
30 minutes
About 3 years and 313 days
5 minutes
About 234 days and 17 hours
1 hour
About 7 years and 261 days
Technical data of the sensors
CO
2
 Carbon Dioxide
Sensor
NDIR Dual Wavelength
Measurement range
0 ... 5000ppm
Sensor working range
-5 ... 50°C
Accuracy
±50ppm+3% of measurement
Resolution
1ppm
Temperature dependence
0.1%f.s./°C
Response time (T
90
)
< 120 sec (air speed = 2m/sec)
Long-term stability
5% of measurement/5 years
HD21AB17
CO Carbon Monoxide
Sensor
Electrochemical cell
Measurement range
0 ... 500ppm
Sensor working range
-5 ... 50°C
Accuracy
±3ppm+3% of measurement
Resolution
1ppm
Response time (T
90
)
< 50 sec
Long-term stability
5% of measurement/year
Service life
> 5 years in normal environment conditions
Atmospheric Pressure Patm
Type of sensor
Piezo-resistive
Measurement range
750 ... 1100 hPa
Accuracy
±1.5 hPa @ 25°C
Resolution
1 hPa
Long-term stability
2hPa/year
Temperature drift
±3hPa with temperature -20 ... +60°C
Relative Humidity RH (HD21AB17 only)
Type of sensor
Capacitive
Sensor protection
Stainless steel grid filter (on request 20μm sin-
tered filter P6 in AISI 316 or 10μm sintered filter
P7 in PTFE)
Measurement range
0 ... 100 % RH
Sensor working range
-20 ... +60°C
Accuracy
±2% (10÷90% RH) ±2.5% in the remaining range
Resolution
0.1°C
Temperature dependence
±2% on all temperature range
Hysteresis and repeatability
1% RH
Response time (T90)
< 20 sec (air speed = 2m/sec) without filter
Long-term stability
1%/year
Temperature T (HD21AB17 only)
Type of sensor
NTC 10kΩ

Measurement range
-20 ... +60°C
Accuracy
±0.2°C ±0.15% of measurement
Resolution
0.1°C
Response time (T
90
)
< 30 sec (air speed = 2m/sec)
Long-term stability
0.1°C/year
ORDERING CODES
HD21AB:
IAQ  Monitor  datalogger  kit.  It  measures  CO,  CO2  and  atmospheric pressure. Equipped with:
DeltaLog10
 software (version 0.1.5.3 and later)
for data download, monitor, and data processing on Personal Computer, 4
x 1.2V NiMH rechargeable batteries, operating manual, case.
The cables
must be ordered separately.
HD21AB17:
IAQ  Monitor  datalogger  kit.  It  measures  CO,  CO
2
,  atmospheric
pressure,  temperature  and  relative  humidity.  Equipped  with:
DeltaLog10
software (
version 0.1.5.3 and later
) for data download, monitor, and data
processing on Personal Computer, 4 x 1.2V NiMH rechargeable batteries,
operating manual, case.


Không có nhận xét nào:

Đăng nhận xét

HD 2110L , HD 2110L Delta Ohm , HD 2110L Delta Ohm Vietnam

HD 2110L , HD 2110L Delta Ohm , HD 2110L Delta Ohm Vietnam GHM Group, GHM Group Vietnam,  Dai Ly Detal Ohm , Dai Ly Detal Ohm Vietnam , De...