Working relative humidity
Dai Ly Detal Ohm, Dai Ly Detal Ohm Vietnam, Detal Ohm, Detal Ohm Viet Nam, Detal Ohm Vietnam, GHM Group, GHM Group Vietnam,
Working relative humidity
0 ... 85% RH no condensation
Protection degree
IP 64
Power supply
Power adapter (cod. SWD05)
5Vdc/1A
Stored data security
unlimited
Serial interface:
output for connection to the PC by using
the USB cable CP24
Storage capacity:
96,000 recordings, corresponding to
approximately 26 hours of continuous
data acquisition.
Storage interval:
fi xed at 1 second.
Measuring ranges
Measurement of the
illuminance in the
spectral range 380...780 nm
Measurement of the
ultraviolet radiation in
the spectral UVA range (315...400 nm)
Measurement of infrared
radiation in the
spectral fi eld 700...1300 nm, with
spectral weighting factor R(
Measurement of infrared
radiation, spectral
range 400...2800 nm
0
ORDERING CODES
HD2402:
Multi-sensor
instrument, data logger,
for measuring noncoherent
optical radiation.
Equipped with:
DeltaLog13
software (version 1.0.1.0)
to download, monitor
and
process the data
on a personal
computer, hardware key
CH20-ROA
to enable the
software,
CP24 connection
cable,
SWD05
external power
supply,
VTRAP20
tripod,
manual, carrying case.
Accessories:
CH20-ROA: Hardware key
for PC with Windows
®
operating systems.
Inserted into a USB port
enables the use of PC software DeltaLog13 with the
instrument HD2402.
DeltaLog13:
Additional copy of the software for the confi guration of
the instrument and the
data download by the PC connection. Suitable for Windows
®
operating systems.
CP24:
Connection cable to
a PC or
to the external
power supply. M12
connector on the
instrument side and USB type A- connector on the PC / Power
Supply side.
SWD05:
Stabilized external power supply 100...240Vac/5Vdc-1A.
Output with USB connector
type A.
VTRAP20:
Tripod to fi x the instrument, maximum height 270 mm
The
HD2402
is a portable photo-radiometer data
logger for the measurement of
non-
coherent optical radiation in
compliance with the European Directive 2006/25/EC and
the legislative decree n. 81 of
April 9
th
2008
.
The instrument is equipped with a
series of sensors to cover different spectral portions and a
small laser suitable to indicate the
analyzed source.
The various sensors work in the
following spectral ranges:
•
Photometric sensor for measuring
illuminance (lux meter) in the spectral range 380...780 nm.
•
Radiometric sensor for the UV band
(220...400 nm) with spectral weighting factor S(
λ
).
•
Radiometric sensor for UVA band
(315...400 nm).
•
Radiometric sensor for the band 400...700
nm (blue) with spectral weighting factor B (
λ
).
•
Radiometric sensor for the IR band
(700...1300 nm) with spectral weighting factor R(
λ
).
•
Thermopile sensor for the
measurement of irradiance in the infrared spectral range
400...2800 nm.
The
HD2402
can be power supplied either by the
connection to a PC, receiving power supply
directly from the USB port of the
PC, or by an external power supply with USB output (code
SWD05
). The connection cable
CP24
is equipped with an M12 connector on
the instrument
side and a USB type connector for
the PC side or to the power supply SWD05 side.
By using the
software DeltaLog13
from the version 1.0.1.0
and a PC, the
HD2402
can
be confi gured (calendar, date,
time, starting time and duration of the logging) as well as
performing the download and the
analysis of the data stored and the acquisition of data in real
time. Once confi gured, the data
logger can be disconnected from the PC and connected to its
external power supply for the
acquisition and storage of data according to the programmed
settings.
Instrument specifi cations
Instrument
Dimensions
(Length x Width x Height)
69x69x155 mm
74x74x155 mm with protective shell
Weight
500 g
Materials
Aluminium alloy
Protective shell
Rubber
Operating conditions
Working temperature
-5 ... 50°C
Storage temperature
-25 ... 65°C